Configuration register 0 for channel 7
TIMER_SEL_CH | Configures which timer is channel %s selected.\0: Select timer0\1: Select timer1\2: Select timer2\3: Select timer3 |
SIG_OUT_EN_CH | Configures whether or not to enable signal output on channel %s.\0: Signal output disable\1: Signal output enable |
IDLE_LV_CH | Configures the output value when channel %s is inactive. Valid only when LEDC_SIG_OUT_EN_CH%s is 0.\0: Output level is low\1: Output level is high |
PARA_UP_CH | Configures whether or not to update LEDC_HPOINT_CH%s, LEDC_DUTY_START_CH%s, LEDC_SIG_OUT_EN_CH%s, LEDC_TIMER_SEL_CH%s, LEDC_DUTY_NUM_CH%s, LEDC_DUTY_CYCLE_CH%s, LEDC_DUTY_SCALE_CH%s, LEDC_DUTY_INC_CH%s, and LEDC_OVF_CNT_EN_CH%s fields for channel %s, and will be automatically cleared by hardware.\0: Invalid. No effect\1: Update |
OVF_NUM_CH | Configures the maximum times of overflow minus 1.The LEDC_OVF_CNT_CH%s_INT interrupt will be triggered when channel %s overflows for (LEDC_OVF_NUM_CH%s + 1) times. |
OVF_CNT_EN_CH | Configures whether or not to enable the ovf_cnt of channel %s.\0: Disable\1: Enable |
OVF_CNT_RESET_CH | Configures whether or not to reset the ovf_cnt of channel %s.\0: Invalid. No effect\1: Reset the ovf_cnt |